How to resolve 'CMOS Checksum Failure' on NEC Server?
- LLinda PhelpsAug 21, 2025
If you're getting a 'CMOS Checksum Failure' error on your NEC Server, execute SETUP to correct the setting.
How to resolve 'CMOS Checksum Failure' on NEC Server?
If you're getting a 'CMOS Checksum Failure' error on your NEC Server, execute SETUP to correct the setting.
What to do if NEC Server system cannot be operated?
If the NEC Server system cannot be operated for some reason, use Recovery Console to restore the system.
What to do if access is denied in NEC Server Recovery Console?
If an 'Access is denied' message appears in Recovery Console, it means the local security settings are not configured correctly. To resolve this, enable the Security Setting 'Recovery console: Allow floppy copy and access to all drives and all folders'.
Why PROSet II does not start after NEC Express 5800 Server system update?
If PROSet II doesn't start after updating the NEC Server system, it may be because the update was performed without rebooting after breaking dual LAN configuration and uninstalling PROSet II. To fix this, install PROSet II again by running c:\pnpdrvrs\procomp /proset /s from the command prompt.
What to do if files on the hard disk cannot be updated on the NEC Express 5800 Recovery Console?
If files on the hard disk cannot be updated on the Recovery Console, it's because these settings were not configured before using Recovery Console. Enable the Security Setting for 'Recovery console: Allow floppy copy and access to all drives and all folders' in Local Security Policy.
What to do if dynamic disk cannot be written from NEC Express 5800 Server Recovery Console?
If a dynamic disk cannot be written from Recovery Console due to default settings, set AllowRemovableMedia to TRUE.
What to do if dynamic disk can’t be updated after the NEC Express 5800 Recovery Console settings are not applied?
If the dynamic disk can’t be updated after the Recovery Console settings are not applied, set AllowRemovableMedia to TRUE before using the Recovery Console.
What to do if press F5 and F6 keys are not displayed when starting NEC Express 5800 Server Recovery Console?
If the 'Press F5 and F6 keys' are not displayed when starting Recovery Console, immediately press F5 and F6 when 'Press F6 if you need to install a third party SCSI or RAID driver...' is displayed.
How to fix 'Date/Time not set' on NEC Server?
To resolve the 'Date/Time not set' error on your NEC Server, activate the BIOS SETUP utility to set the date and time.
What to do if NEC Server shows 'Insert Key Pressed'?
If you encounter the 'Insert Key Pressed' error on your NEC Server, first release the key that is pressed. Then, try reconnecting the keyboard to ensure it is properly connected.