Page.21
■ For B120e-h
chapter section paraphrased contents
3
1 (1)
POST Error Message
Wrong: There isn't description of the next error messages in the table.
Correct:
Error Message Cause Solution
A804
Latest memory module is
corrupted.
Fail of the BIOS Flash ROM was
detected.
Contact your sales
representative.
B200 Onboard VGA - PCIe Link
Failure
Connection failure of PCIe bus
was detected on onboard VGA.
B201
Onboard LAN 1 – PCIe Link
Failure
Connection failure of PCIe bus
was detected on onboard LAN1
B202 Onboard LAN 2 - PCIe Link
Failure
Connection failure of PCIe bus
was detected on onboard LAN2
B220
Onboard VGA - PCIe Link
Width
Error
Link Width error was detected
on onboard VGA.
B221
Onboard LAN 1 – PCIe Link
Width Error
Link Width error was detected
on onboard LAN1.
B222
Onboard LAN 2 – PCIe Link
Width Error
Link Width error was detected
on onboard LAN2.
B260
Onboard VGA - PCIe Link
Speed Error
Link Speed error was detected on
onboard VGA.
B261 Onboard LAN 1 – PCIe Link
Speed Error
Link Speed error was detected
on onboard LAN1.
B262 Onboard LAN 2 – PCIe Link
Speed Error
Link Speed error was detected
on onboard LAN2.
B2A1 Mezzanine Slot 1 -
PCIE Link
Speed Error
Link Speed error was detected on
Mezzanine Slot 1.
B2A2 Mezzanine Slot 2 -
PCIE Link
Speed Error
Link Speed error was detected on
Mezzanine Slot 2.
B2A3 Mezzanine Slot 3 -
PCIE Link
Speed Error
Link Speed error was detected on
Mezzanine Slot 3.
B2A4 Mezzanine Slot 4 -
PCIE Link
Speed Error
Link Speed error was detected on
Mezzanine Slot 4.
B2A8 PCI Slot - PCIE Link Speed
Error
Link Speed error was detected on
PCI Slot PCIE.
B2AA I/O Blade PCI Slot -
PCIE Link
Speed Error
Link Speed error was detected on
I/O Blade PCI Slot.
Contact your sales
representative.
B330 Expansion ROM not initialized
- PCI Slot
Option ROM expansion in PCI
slot failed.
Disable expansion of option
ROM of the option board that
is not used for OS boot.