Page.22
■ For B120e-h
chapter section paraphrased contents
3
1 (1)
POST Error Message
Wrong: There isn't description of the next error messages in the table.
Correct:
Error Message Cause Solution
B341 Mezzanine Slot 1 -
PCIE Link
Failure
Connection failure of PCIe bus
was detected on Mezzanine Slot
1.
B342 Mezzanine Slot 2 -
PCIE Link
Failure
Connection failure of PCIe bus
was detected on Mezzanine Slot
2.
B343 Mezzanine Slot 3 -
PCIE Link
Failure
Connection failure of PCIe bus
was detected on Mezzanine Slot
3.
B344 Mezzanine Slot 4 -
PCIE Link
Failure
Connection failure of PCIe bus
was detected on Mezzanine Slot
4.
B348 PCI Slot - PCIE Link Failure
Connection failure of PCIe bus
was detected on PCI Slot.
B34A I/O Blade PCI Slot -
PCIE Link
Failure
Connection failure of PCIe bus
was detected on I/O Blade PCI
Slot.
B371 Mezzanine Slot 1 -
PCIE Link
Width Error
Link Width error was detected on
Mezzanine Slot 1.
B372 Mezzanine Slot 2 -
PCIE Link
Width Error
Link Width error was detected on
Mezzanine Slot 2.
B373 Mezzanine Slot 3 -
PCIE Link
Width Error
Link Width error was detected on
Mezzanine Slot 3.
B384 Mezzanine Slot 4 -
PCIE Link
Width Error
Link Width error was detected on
Mezzanine Slot 4.
B378 PCI Slot - PCIE Link Failure
Connection failure of PCIe bus
was detected on PCIe
B37A I/O Blade PCI Slot -
PCIE Link
Width Error
Link Width error was detected on
I/O Blade PCI Slot.
B3A0 CLP Command Failure
CLP Command not executed -
BIOS
B3A1 EM Failure Pause
CLP Command not executed
setting - EM
C400 Can't Read FRU on CPU Unit
TypeI Mezzanine
Can’t read Mezzanine Slot1 FRU
.
C401 Can't Read FRU on CPU Unit
TypeII Mezzanine
Can’t read Mezzanine Slot2 FRU
.
Contact your sales
representative.