5-12
4.5 Insulation Resistance Test
An insulation resistance should be measured under the conditions specified below, in order to confirm that
the requirements of the judgment standard are met.
1) Measuring conditions
Measuring instrument: 500V DC MEGOHM Meter
Testing point: Between the power circuit block and the exposed metallic block
(D-SUB connector)
Measured value readout: A test voltage should be applied for one minute and the resistance
value should be read out thereafter.
2) Judgment standard: 10M or more