5-18
13) If the writing of EDID data is completed normally, EDID WP will be returned to "1 (ON)" and Factory mode
will be closed.
14) Upon the normal completion of EDID data writing, press the [Exit] button to close the program.
5.4.2 EDID Data Inspection and Writing to the DVI Connector (Digital)
1) Connect the EDID data writing unit with jigs, etc. (Refer to a Fig.5.1.2 DVI-D connector connection figure)
2) The "BACK" button is pushed twice and the [MODEL SELECT] screen is displayed. Cursor is united and
double-clicked to [LCD1970NX (DVI-D)].
3) 6) to 14) is carried out in the procedure of the "5.4.1 EDID Data Inspection and Writing to the D-SUB
Connector (Analog) ".