English−61
Proof of Play
This function allows sending of messages for the current status of the monitor by self-diagnosis.
For the Proof of Play function including self-diagnosis, please see the “External_Control.pdf”. See page 73.
Check item Message
a
INPUT DisplayPort, HDMI1, HDMI2, Media Player, COMPUTE MODULE, OPTION*
b
Resolution e.g. (H)1920, (V)1080, (H)3840, (V)2160 or No signal or Invalid signal
c
Audio signal Audio in or No Audio in or N/A
d
Picture Image Normal Picture or No Picture
e
AUDIO OUT Normal Audio or No Audio
f
TIME (year)/(month)/(day)/(hour)/(minutes)/(second)
g
EXPANSION DATA
00h: Normal Proof of Play event
01h: Proof of Play event is “last power on time”
10h: MEDIA PLAYER is stop
11h: MEDIA PLAYER is start
12h: MEDIA PLAYER is pause
13h: MEDIA PLAYER error occur
40h: Human detected (Human sensor Status)
41h: Human detect cleared (Human Sensor Status)
*: This function depends on which Option Board is installed in the monitor.
Example:
a
HDMI1
b
3840 x 2160
c
Audio in
d
Normal Picture
e
Normal Audio
f
2020/1/1/0h/0m/0s
g
10h: MEDIA PLAYER is stop