©NEC Display Solutions, Ltd. 2014-2020 13
3. Command details
3.1 [ 009. ERROR STATUS REQUEST ]
Gets information about errors occurring in the projector.
Command
00h 88h 00h 00h 00h 88h
Response
When the command succeeds
20h 88h <ID1> <ID2> 0Ch <DATA01> - <DATA12> <CKS>
When the command fails
A0h 88h <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>
Data part
DATA1 - DATA12 .............. Error information is provided. A bit set to "0" indicates that the data is normal, and a bit
set to "1" indicates an error. For an error information list, see the next page.