– 89 –
CHAPTER 4 OFFICE DATA DESIGN
Data Programming
STEP 1: ASYD- SYS1, INDEX449, b2: 0 = Timer control
STEP 2: ARTD- Assign Route data for Announcement Route.
CDN1 (OSGS) = 2 (Second Dial Tone)
CDN2 (ONSG) = 2 (PB)
CDN5 (TF) = 1 (OGT)
CDN6 (TCL) = 4 (Tie Line)
CDN7 (L/T) = 1 (Trunk)
CDN28 (ANS) = 0 (No answer signal is given)
Note: All CDNs other than the above should be set “0”.
STEP 3: AIVSL- Assign the announcement trunk (VS) data
VS-CH: Assign the channel number of the announcement trunk (VS).
KIND=ANNC
RT: Assign Route number
TK: Assign Trunk number
LENS: Assign Line Equipment Number
TN: Assign Tenant number
STEP 4: AADT- Assign Announcement/Dictation Trunks.
TYPE:1 = Announcement Trunk
NO: Announcement number (1~58)
D: 1 = Disconnect Timer is available
CP: Announcement Connection Pattern Note 1
1 = Single connection
MSGT:Message Timer (2-120 sec.) Note 2
WAIT:Waiting Timer (0 sec.) Note 1 Note 3
RT: RT No.Note 4
TRK:TRK No.Note 5
STEP 5: MBTK- Cancel the make busy status.
STEP 6: ARRC- Allow the connection between Incoming Route and Dummy Route.
ICRT = 1~255 (Incoming Route Number)
OGRT = RT No. assigned by the AIVSL/AADT command
ARI-A_RES =1 (Allowed)
ARI-D_RES =1 (Allowed)
STEP 7: ACDCCV ACD Call Control Vector
Tenant number (1-9)
CCVNO: CCV index number (1-900)
CCVACT: 2 (Announcement)
CCVACT DATA: Announcement No. (1-58)