Nelweld Operations and Service Manual
- 56 -
Description
Default
Value
Minimum
Value
Maximum
Value
Units
Zero state One state
Comments
F111
Preset-Enabled Lock Mode 0 0 1 disabled enabled
Enable to allow preset selections
while locked.
F112
Loadbank Mode Enable 0 0 1 disabled enabled
Enable to allow for supply of
weld current through a fixed
resistive load.
F113
Stud Feed Weld Success Enable 0 0 1 disabled enabled
Enable to suppress stud feed
signal under all conditions other
than a successful weld.
F114
Calibration Factor 0 -200 +200
Offset adjustment factor for
calibrating the Nelweld
F115
KFL Mode Enable 0 0 1 disabled enabled
Enable only when using a KFL
gun.
F116
Quick Pilot Arc Mode 1 0 1 disabled enabled
Enable to fire main arc as soon
as pilot arc is established.