Problem Reason Solution
6. orange and lazy re, piled pellet,
carbon on the glass
Lack of air intake for
burning.
Clean the block in gate bar.
Check the door and window
glass gasket sealed or not.
Check the air intake pipe
and venting pipe blocked or
not, and clean it.
Change to the big diameter
pipes if pipes are too long to
a󰀨ect combustion.
Raise the combustion fan‘s
speed.
Call the dealer to reset the
program
7. The re went out and power went
o󰀨 automatically.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
Low temperature switch
(30˚C) is wrong.
Set temperature is reached
Put fuel into the hopper.
refer to (2)
Lower the speed of
combustion fan
Cool the stove at least 1
hour then operate again or
change the low temperature
switch (30˚C).
„ECO“ its normal, waiting,
after the temperature is
below set on, it will auto-
matically switch on again
8. The blower still works after the
stove is cool and fuel feed stops.
The low temperature switch
(30˚C) is broken.
Change this switch.
9. Not enough heat wind Unqualied fuel
Blower speed is too low or
not running.
Heat exchange tubes or ue
pass are dirty.
Use the standard special pellet.
Change the blower(Broken) or
the mother board is broken
Clean the heat exchange
tubes or ue pass.
10. Showing „E5“ on the display Vent pipe is blocked
The door is opening or seal
needs to be replaced
The are some leakages
Shut down the stove, check
the venting pipe
Close the door or change the
seal. Check it and repair it.
Raise the combustion fan‘s
speed to o󰀨er more
pressure in the stove