4. If automatic giveback was disabled, reenable it: storage failover modify -node local -auto-giveback true
Step 6: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part Return
& Replacements
page for further information.
Replace system management module - AFF A70, AFF A90
The System Management module, located at the back of the controller in slot 8, contains
onboard components for system management, as well as ports for external management.
The target controller must be shut down to replace an impaired System Management
module or replace the boot media.
The System Management module has the following onboard components:
Boot media, allowing boot media replacement without removing the controller module.
BMC
Management switch
The System Management module also contains the following ports for external management:
RJ45 Serial
USB Serial (Type-C)
USB Type-A (Boot recovery)
e0M RJ45 Ethernet
To replace the System Management module or or the boot media, you must shut down the impaired controller.
Before you begin
This procedure uses the following terminology:
The impaired controller is the controller on which you are performing maintenance.
The healthy controller is the HA partner of the impaired controller.
All other system components must be working properly.
The partner controller must be able to take over the impaired controller.
You must replace the failed component with a replacement FRU component you received from your
provider.
Step 1: Shut down the impaired controller
Shut down or take over the impaired controller using one of the following options.