See Disk ownership changes during HA takeover and MetroCluster switchover in a four-node
MetroCluster configuration
for more information.
8. If your system is in a MetroCluster configuration, verify that each controller is configured: metrocluster node
show - fields configuration-state
node1_siteA::> metrocluster node show -fields configuration-state
dr-group-id cluster node configuration-state
----------- ---------------------- --------------
-------------------
1 node1_siteA node1mcc-001 configured
1 node1_siteA node1mcc-002 configured
1 node1_siteB node1mcc-003 configured
1 node1_siteB node1mcc-004 configured
4 entries were displayed.
9.
Verify that the expected volumes are present for each controller:
vol show -node node-name
10. If storage encryption is enabled, you must restore functionality.
11. If you disabled automatic takeover on reboot, enable it from the healthy controller: storage failover modify
-node replacement-node-name -onreboot true
12.
If AutoSupport is enabled, restore/unsuppress automatic case creation by using the
system node
autosupport invoke -node * -type all -message MAINT=END
command.
Step 6: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part Return
& Replacements
page for further information.
Replace the NV battery - AFF A70, AFF A90
To replace the NV battery, you must remove the controller module, remove the battery,
replace the battery, and then reinstall the controller module.
All other components in the system must be functioning properly; if not, you must contact technical support.
Step 1: Shut down the impaired controller
Shut down or take over the impaired controller using one of the following options.
66