◦ If the command fails because of an NDMP, SnapMirror, or SnapVault process, disable the process. See
the appropriate Documentation Center for more information.
3. Wait 3 minutes and check the failover status with the storage failover show command.
4. At the clustershell prompt, enter the network interface show -is-home false command to list the logical
interfaces that are not on their home controller and port.
If any interfaces are listed as
false, revert those interfaces back to their home port using the net int revert
-vserver Cluster -lif _nodename command.
5. Move the console cable to the target controller and run the version -v command to check the ONTAP
versions.
6.
Use the
storage encryption disk show to review the output.
7. Use the security key-manager key query command to display the key IDs of the authentication keys that
are stored on the key management servers.
◦
If the
Restored column = yes/true, you are done and can proceed to complete the replacement
process.
◦
If the
Key Manager type = external and the Restored column = anything other than yes/true,
use the security key-manager external restore command to restore the key IDs of the authentication
keys.
If the command fails, contact Customer Support.
◦
If the
Key Manager type = onboard and the Restored column = anything other than yes/true,
use the security key-manager onboard sync command to synchronize the missing onboard keys on the
repaired node.
Use the security key-manager key query command to verify that the
Restored column = yes/true
for all authentication keys.
8. Connect the console cable to the partner controller.
9.
Give back the controller using the
storage failover giveback -fromnode local command.
10. Restore automatic giveback if you disabled it by using the storage failover modify -node local -auto
-giveback true command.
11. If AutoSupport is enabled, restore/unsuppress automatic case creation by using the system node
autosupport invoke -node * -type all -message MAINT=END command.
Return the failed part to NetApp - AFF A70, AFF A90
Return the failed part to NetApp, as described in the RMA instructions shipped with the
kit. See the
Part Return & Replacements page for further information.
Chassis
Replace the chassis - AFF A70, AFF A90
To replace the chassis, you must move the bezel, controller modules, and NVMe drives
from the impaired chassis to the replacement chassis, and then remove the impaired
19