You must run this command from the LOADER prompt for system-level diagnostics to
function properly. The boot_diags command starts special drivers designed specifically for
system-level diagnostics.
3.
Run diagnostics on the device causing problems by entering the following command:
sldiag device
run [-dev devtype|mb|slotslotnum] [-name device]
â—¦ -dev devtype specifies the type of device to be tested.
â–ª
ata is an Advanced Technology Attachment device.
â–ª
bootmedia is the system booting device..
â–ª
cna is a Converged Network Adapter not connected to a network or storage device.
â–ª
env is motherboard environmentals.
â–ª
fcache is the Flash Cache adapter, also known as the Performance Acceleration Module 2.
â–ª
fcal is a Fibre Channel-Arbitrated Loop device not connected to a storage device or Fibre
Channel network.
â–ª
fcvi is the Fiber Channel Virtual Interface not connected to a Fibre Channel network.
â–ª
interconnect or nvram-ib is the high-availability interface.
â–ª
mem is system memory.
â–ª
nic is a Network Interface Card not connected to a network.
â–ª
nvram is nonvolatile RAM.
â–ª
nvmem is a hybrid of NVRAM and system memory.
â–ª
sas is a Serial Attached SCSI device not connected to a disk shelf.
â–ª
serviceproc is the Service Processor.
â–ª
storage is an ATA, FC-AL, or SAS interface that has an attached disk shelf.
â–ª
toe is a TCP Offload Engine, a type of NIC.
â—¦
mb specifies that all the motherboard devices are to be tested.
â—¦ `slot`slotnum specifies that a device in a specific slot number is to be tested.
â—¦
-name device specifies a given device class and type.
4.
View the status of the test by entering the following command:
sldiag device status
Your storage system provides the following output while the tests are still running:
There are still test(s) being processed.
After all the tests are complete, the following response appears by default:
*> <SLDIAG:_ALL_TESTS_COMPLETED>
1455

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals