Error Count: 2 Run Time: 70 secs
>>>>> ERROR, please ensure the port has a shelf or plug.
END DATE: Sat Jan 3 23:12:07 GMT 2009
LOOP: 1/1
TEST END --------------------------------------------
If the system-level diagnostics
tests…
Then…
Resulted in some test failures Determine the cause of the problem.
a.
Exit Maintenance mode by entering the following command:
halt
b. Perform a clean shutdown and disconnect the power supplies.
c. Verify that you have observed all the considerations identified for
running system-level diagnostics, that cables are securely
connected, and that hardware components are properly installed
in the storage system.
d. Reconnect the power supplies and power on the storage system.
e. Repeat Steps 1 through 5 of Running device failure diagnostics.
Resulted in the same test failures Technical support might recommend modifying the default settings on
some of the tests to help identify the problem.
a. Modify the selection state of a specific device or type of device on
your storage system by entering the following command:
sldiag
device modify [-dev devtype|mb|slot_slotnum_] [-
name device] [-selection
enable|disable|default|only]
-selection enable|disable|default|only allows you to
enable, disable, accept the default selection of a specified device
type or named device, or only enable the specified device or
named device by disabling all others first.
b. Verify that the tests were modified by entering the following
command:
sldiag option show
c. Repeat Steps 3 through 5 of Running device failure diagnostics.
d. After you identify and resolve the problem, reset the tests to their
default states by repeating substeps 1 and 2.
e. Repeat Steps 1 through 5 of Running device failure diagnostics.
1457