If your system is running
ONTAP…
Then…
With two nodes in the cluster
Issue these commands: node::> cluster ha modify
-configured true node::> storage failover modify
-node node0 -enabled true
With more than two nodes in the
cluster
Issue this command: node::> storage failover modify
-node node0 -enabled true
In a stand-alone configuration You have no further steps in this particular task.
You have completed system-level diagnostics.
Resulted in some test failures Determine the cause of the problem.
a.
Exit Maintenance mode:
halt
b. Perform a clean shutdown, and then disconnect the power
supplies.
c. Verify that you have observed all of the considerations identified
for running system-level diagnostics, that cables are securely
connected, and that hardware components are properly installed
in the storage system.
d. Reconnect the power supplies, and then power on the storage
system.
e. Rerun the system-level diagnostics test.
Step 3: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part Return
& Replacements
page for further information.
Controller module
Overview of controller module replacement - FAS2600
You must review the prerequisites for the replacement procedure and select the correct
one for your version of the ONTAP operating system.
All drive shelves must be working properly.
If your system is in an HA pair, the healthy controller must be able to take over the controller that is being
replaced (referred to in this procedure as the “impaired controller”).
This procedure includes steps for automatically or manually reassigning drives to the replacement
controller, depending on your system’s configuration.
You should perform the drive reassignment as directed in the procedure.
You must replace the failed component with a replacement FRU component you received from your