11. Connect the console cable to the partner controller.
12.
Give back the controller using the
storage failover giveback -fromnode local command.
13.
Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Return the failed part to NetApp - AFF fas8300 and FAS8700
Return the failed part to NetApp, as described in the RMA instructions shipped with the
kit. See the
Part Return & Replacements page for further information.
Replace the caching module - FAS8300 and FAS8700
You must replace the caching module in the controller module when your system
registers a single AutoSupport (ASUP) message that the module has gone offline; failure
to do so results in performance degradation.
You must replace the failed component with a replacement FRU component you received from your
provider.
Step 1: Shut down the impaired controller
You can shut down or take over the impaired controller using different procedures,
depending on the storage system hardware configuration.
439