are required because the failure is restricted to an HA pair and storage failover commands can be used to
provide nondisruptive operation during the replacement.
You must replace the failed component with a replacement FRU component you received from your
provider.
You must be replacing a controller module with a controller module of the same model type. You cannot
upgrade your system by just replacing the controller module.
You cannot change any drives or drive shelves as part of this procedure.
In this procedure, the boot device is moved from the impaired node to the replacement node so that the
replacement node will boot up in the same version of ONTAP as the old controller module.
It is important that you apply the commands in these steps on the correct systems:
The impaired node is the node that is being replaced.
The replacement node is the new node that is replacing the impaired node.
The healthy node is the surviving node.
You must always capture the node’s console output to a text file.
This provides you a record of the procedure so that you can troubleshoot any issues that you might
encounter during the replacement process.
Shut down the impaired controller
Shut down or take over the impaired controller using the appropriate procedure for your
configuration.