synchronize.
◦ If the command fails because of an NDMP, SnapMirror, or SnapVault process, disable the process. See
the appropriate content for more information.
5.
Wait 3 minutes and check the failover status with the
storage failover show command.
6.
At the clustershell prompt, enter the
net int show -is-home false command to list the logical
interfaces that are not on their home node and port.
If any interfaces are listed as
false, revert those interfaces back to their home port using the net int
revert
command.
7.
Move the console cable to the target node and run the
version -v command to check the ONTAP
versions.
8.
Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
9.
Use the
storage encryption disk show at the clustershell prompt, to review the output.
10.
Use the
security key-manager key-query command to display the encryption and authentication
keys that are stored on the key management servers.
◦
If the
Restored column = yes/true, you are done and can proceed to complete the replacement
process.
◦
If the
Key Manager type = external and the Restored column = anything other than yes/true,
use the
security key-manager external restore command to restore the key IDs of the
authentication keys.
If the command fails, contact Customer Support.
◦
If the
Key Manager type = onboard and the Restored column = anything other than yes/true,
use the
security key-manager onboard sync command to re-sync the Key Manager type.
Use the
security key-manager key-query command to verify that the Restored column =
yes/true for all authentication keys.
11. Connect the console cable to the partner node.
12.
Give back the node using the
storage failover giveback -fromnode local command.
13.
Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Return the failed part to NetApp - FAS9500
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part Return
& Replacements
page for further information.
Hot-swap a caching module - FAS9500
The NVMe SSD FlashCache modules (FlashCache or caching modules) are located in
the front of the NVRAM11 module in Slot 6 of FAS9500 systems. You can hot-swap the
caching module of the same capacity from the same or different supported vendor.