4.
Enable the interconnect diagnostics tests from the Maintenance mode prompt:
sldiag device modify
-dev interconnect -sel enable
The interconnect tests are disabled by default and must be enabled to run separately.
5.
Run the interconnect diagnostics test from the Maintenance mode prompt:
sldiag device run -dev
interconnect
You only need to run the interconnect test from one controller.
6.
Verify that no hardware problems resulted from the replacement of the chassis:
sldiag device status
-dev interconnect -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status of
failures resulting from testing the component.
7. Proceed based on the result of the preceding step.
If the system-level diagnostics tests… Then…
Were completed without any failures a.
Clear the status logs:
sldiag device
clearstatus
b.
Verify that the log was cleared:
sldiag device
status
The following default response is displayed:
SLDIAG: No log messages are
present.
c.
Exit Maintenance mode on both controllers:
halt
The system displays the LOADER prompt.
You must exit Maintenance mode
on both controllers before
proceeding any further.
d. Enter the following command on both controllers
at the LOADER prompt: bye
e. Return the node to normal operation.
If your system is running ONTAP… Then…
With two nodes in the cluster
Issue these commands: node::> cluster ha
modify -configured true
node::> storage failover modify -node
node0 -enabled true