The system ID and disk assignment information reside in the NVRAM module, which is in a
module separate from the controller module and not impacted by the controller module
replacement.
Step 2: Reassign disks
If the storage system is in an HA pair, the system ID of the new controller module is automatically assigned to
the disks when the giveback occurs at the end of the procedure. You must confirm the system ID change when
you boot the replacement node and then verify that the change was implemented.
This procedure applies only to systems running ONTAP in an HA pair.
1.
If the replacement node is in Maintenance mode (showing the
*> prompt), exit Maintenance mode and go
to the LOADER prompt:
halt
2.
From the LOADER prompt on the replacement node, boot the node, entering
y if you are prompted to
override the system ID due to a system ID mismatch.
boot_ontap
3.
Wait until the
Waiting for giveback… message is displayed on the replacement node console and
then, from the healthy node, verify that the new partner system ID has been automatically assigned:
storage failover show
In the command output, you should see a message that the system ID has changed on the impaired node,
showing the correct old and new IDs. In the following example, node2 has undergone replacement and has
a new system ID of 151759706.
node1> storage failover show
Ê Takeover
Node Partner Possible State Description
------------ ------------ --------
-------------------------------------
node1 node2 false System ID changed on
partner (Old:
Ê 151759755, New:
151759706), In takeover
node2 node1 - Waiting for giveback
(HA mailboxes)
4. From the healthy node, verify that any coredumps are saved:
a.
Change to the advanced privilege level:
set -privilege advanced
You can respond Y when prompted to continue into advanced mode. The advanced mode prompt
appears (*>).
b.
Save any coredumps:
system node run -node local-node-name partner savecore
c. Wait for the savecore command to complete before issuing the giveback.
You can enter the following command to monitor the progress of the savecore command:
system
node run -node local-node-name partner savecore -s
749