b.
Save any coredumps:
system node run -node local-node-name partner savecore
c.
Wait for
savecore command to complete before issuing the giveback.
You can enter the following command to monitor the progress of the
savecore command: system
node run -node local-node-name partner savecore -s
d.
Return to the admin privilege level:
set -privilege admin
5. Give back the node:
a.
From the healthy node, give back the replaced node’s storage:
storage failover giveback
-ofnode replacement_node_name
the replacement node takes back its storage and completes booting.
If you are prompted to override the system ID due to a system ID mismatch, you should enter
y.
If the giveback is vetoed, you can consider overriding the vetoes.
Find the High-Availability Configuration Guide for your version of ONTAP 9
b. After the giveback has been completed, confirm that the HA pair is healthy and that takeover is
possible:
storage failover show
The output from the storage failover show command. should not include the System ID changed
on partner message.
6.
Verify that the disks were assigned correctly:
storage disk show -ownership
The disks belonging to the replacement node should show the new system ID. In the following example,
the disks owned by node1 now show the new system ID, 1873775277:
node1> storage disk show -ownership
Disk Aggregate Home Owner DR Home Home ID Owner ID DR Home ID
Reserver Pool
----- ------ ----- ------ -------- ------- ------- -------
--------- ---
1.0.0 aggr0_1 node1 node1 - 1873775277 1873775277 -
1873775277 Pool0
1.0.1 aggr0_1 node1 node1 1873775277 1873775277 -
1873775277 Pool0
.
.
.
Option 2: Manually reassign the system ID on systems in a two-node MetroCluster configuration