controller_A_1::> metrocluster heal -phase aggregates
[Job 130] Job succeeded: Heal Aggregates is successful.
If the healing is vetoed, you have the option of reissuing the metrocluster heal command with the
-override-vetoes parameter. If you use this optional parameter, the system overrides any soft vetoes that
prevent the healing operation.
4. Verify that the operation has been completed by using the metrocluster operation show command.
controller_A_1::> metrocluster operation show
Ê Operation: heal-aggregates
Ê State: successful
Start Time: 7/25/2016 18:45:55
Ê End Time: 7/25/2016 18:45:56
Ê Errors: -
5.
Check the state of the aggregates by using the
storage aggregate show command.
controller_A_1::> storage aggregate show
Aggregate Size Available Used% State #Vols Nodes RAID
Status
--------- -------- --------- ----- ------- ------ ----------------
------------
...
aggr_b2 227.1GB 227.1GB 0% online 0 mcc1-a2
raid_dp, mirrored, normal...
6.
Heal the root aggregates by using the
metrocluster heal -phase root-aggregates command.
mcc1A::> metrocluster heal -phase root-aggregates
[Job 137] Job succeeded: Heal Root Aggregates is successful
If the healing is vetoed, you have the option of reissuing the metrocluster heal command with the
-override-vetoes parameter. If you use this optional parameter, the system overrides any soft vetoes that
prevent the healing operation.
7.
Verify that the heal operation is complete by using the
metrocluster operation show command on
the destination cluster:
17

Other manuals for NetApp FAS8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp FAS8300 and is the answer not in the manual?

NetApp FAS8300 Specifications

General IconGeneral
ControllerDual
Maximum Drives1440
Form Factor4U
NVMe Flash CacheSupported
Operating SystemONTAP
High AvailabilityYes
Drive TypesSSD, HDD, NVMe
Connectivity10GbE, 25GbE, 40GbE, 100GbE, FC
ProtocolsNFS, CIFS, iSCSI, FC, FCoE
ProcessorIntel Xeon
Data ReductionYes (compression, deduplication, compaction)
Flash CacheSupported