controller_A_1::> storage aggregate show
Aggregate Size Available Used% State #Vols Nodes RAID
Status
--------- -------- --------- ----- ------- ------ ----------------
------------
...
aggr_b2 227.1GB 227.1GB 0% online 0 mcc1-a2
raid_dp, mirrored, normal...
6.
Heal the root aggregates by using the
metrocluster heal -phase root-aggregates command.
mcc1A::> metrocluster heal -phase root-aggregates
[Job 137] Job succeeded: Heal Root Aggregates is successful
If the healing is vetoed, you have the option of reissuing the metrocluster heal command with the
-override-vetoes parameter. If you use this optional parameter, the system overrides any soft vetoes that
prevent the healing operation.
7.
Verify that the heal operation is complete by using the
metrocluster operation show command on
the destination cluster:
mcc1A::> metrocluster operation show
Ê Operation: heal-root-aggregates
Ê State: successful
ÊStart Time: 7/29/2016 20:54:41
Ê End Time: 7/29/2016 20:54:42
Ê Errors: -
8. On the impaired controller module, disconnect the power supplies.
Move and replace hardware - FAS8300 and FAS8700
Step 1: Remove the controller modules
To replace the chassis, you must remove the controller modules from the old chassis.
Steps
1. If you are not already grounded, properly ground yourself.
2. Release the power cable retainers, and then unplug the cables from the power supplies.
3. Loosen the hook and loop strap binding the cables to the cable management device, and then unplug the
system cables and SFPs (if needed) from the controller module, keeping track of where the cables were
connected.
Leave the cables in the cable management device so that when you reinstall the cable management
device, the cables are organized.
45

Other manuals for NetApp FAS8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp FAS8300 and is the answer not in the manual?

NetApp FAS8300 Specifications

General IconGeneral
ControllerDual
Maximum Drives1440
Form Factor4U
NVMe Flash CacheSupported
Operating SystemONTAP
High AvailabilityYes
Drive TypesSSD, HDD, NVMe
Connectivity10GbE, 25GbE, 40GbE, 100GbE, FC
ProtocolsNFS, CIFS, iSCSI, FC, FCoE
ProcessorIntel Xeon
Data ReductionYes (compression, deduplication, compaction)
Flash CacheSupported