Sequence Of Programming Steps For Dual Barista Controller
• Simultaneously depress and hold the left & middle brew buttons until display lights up (approx. 10 seconds).
• You are now in the Program Mode. Functions to be programmed appear in the order in which they are shown in the
following table.
• Use the middle brew button to cycle through the functions to find the one you wish to change.
• Use the left brew button to raise the displayed value and the right brew button to lower the value. Press middle brew
button to store the changed value and advance to the next function.
• If the brewer detects no activity for approximately 60 seconds it will exit the Program Mode, except as noted below.
Code Function To Set Set Values Available Left Side Right Side
1A Brew 1 time OFF, 30 sec – 8 mins 85 Oz (2:00+/-) 85 Oz (2:00+/-)
1b Brew 2 time OFF, 30 sec – 8 mins 170 Oz (4:00+/-) 170 Oz (4:00+/-)
1c Brew 3 time OFF, 30 sec – 8 mins 255 Oz (6:00+/-) 255 Oz (6:00+/-)
2A Brew 1, double dump feature ON or OFF OFF OFF
2b Brew 2, double dump feature ON or OFF OFF OFF
2c Brew 3, double dump feature ON or OFF OFF OFF
3 Visa - Brew Time OFF, 30 sec – 2.5 mins 1:00 1:00
4
Water Temperature 1
170 F – 205 F 202 202
5 Auto Arm ON or OFF ON ON
6A
Pre-infusion 1 mode 2
ON or OFF OFF OFF
6b
Pre-infusion 2 mode 2
ON or OFF OFF OFF
6c
Pre-infusion 3 mode 2
ON or OFF OFF OFF
7 Pulse brew mode ON or OFF ON ON
7A
Pulse brew 1 time 3
OFF, 30 sec – 8 mins 4:30 4:30
7b
Pulse brew 2 time 3
OFF, 30 sec – 8 mins 5:00 5:00
7c
Pulse brew 3 time 3
OFF, 30 sec – 8 mins 6:30 6:30
8A Audible alert/mode ON or OFF ON ON
8b Audible alert no. of beeps Off, 1 – 9 4 4
9 Coffee freshness monitor 10 mins – 2 hrs
2 HRS
2 HRS
10A Filtering flow rate OFF, 0.25 – 1.00 gal. /min OFF OFF
10b
Filter capacity 4
OFF, 0.50 – 2.50 gal. X 100 OFF OFF
11 Number of brews ON or OFF, Clr N/A N/A
12A
Auto warmer shutoff 5
ON or OFF N/A N/A
12b Time interval before shutoff 0 – 4:15 N/A N/A
13A Power mode Normal, Power Save, Power Down Normal Normal
13b
Power shutdown time 6
30 mins – 4 hrs N/A N/A
End None 7 N/A N/A N/A
1. Brewer will remain in this sequence indefinitely until Cancel button is pressed. Heating icon will track heater operation.
2. Hidden when corresponding brew time is OFF
3. Hidden if pulse brew mode is off or corresponding brew time is OFF.
4. Hidden if filter flow rate is off.
5. Warmer models only.
6. Hidden when power save mode is normal.