EasyManua.ls Logo

Newco CX-TOUCH - Machine Setup and Installation; Plumbing Connections

Newco CX-TOUCH
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Instructions
WARNING: - Read and follow installation instructions before plugging or wiring in machine to
electrical circuit. Warranty will be void if machine is connected to any voltage other than that
specified on the nameplate serial tag.
1) Machine must be on a flat and level surface. Plug or wire in machine to appropriate voltage
as noted on the brewer serial tag. Serial tag is located on side of machine.
2) With water line connected, turn machine power ON (power switch located lower right rear
of machine). Install Drip tray and drip tray grate under brew area (slide tray between guide
rails until seated).
3) Tank will automatically fill, and machine will start heating. If tank does not fill in 8
minutes, a “tank fill error” will occur. (Note: To reset error power machine on/off with
power switch).
4) Allow 10 to 15 minutes for water in tank to heat to brewing temperature. (Additional water
may drip into drip tray on initial expansion of water in the tank). This will not occur
thereafter.
5) Heater will turn on when water in tank is at probe level. If brew is initialized before tank
temperature is reached, machine will display “Preparing to Brew” until temp is reached,
then will start brewing.
6)
In higher altitude locations (3000 feet above sea level) the thermostat may
have to be adjusted lower to prevent boiling:
Brew water temperature is factory set at 200o F (92.3o C) Areas of high altitude will require lowering this
temperature to prevent boiling. This chart should be used as a guide when readjusting the brew water temperature.
Altitude (Feet) Boiling point of water o F o C Recommended water temperature o F o C
-1000
213.8
101.0
200
93.3
-500
212.9
100.5
200
93.3
0
212.0
100.0
200
93.3
500
211.1
99.5
200
93.3
1000
210.2
99.0
200
93.3
1500
209.3
98.5
200
93.3
2000
208.4
98.0
200
93.3
2500
207.4
97.4
200
93.3
3000
206.5
96.9
199
92.8
3500
205.6
96.4
198
92.2
4000
204.7
95.9
197
91.7
4500
203.8
95.4
196
91.1
5000
202.9
94.9
195
90.6
5500
201.9
94.4
195
90.6
6000
201.0
93.9
194
90.0
6500
200.1
93.4
193
89.4
7000
7500
199.2
92.9
198.3
92.4
192
88.9
191
88.3
8000
197.4
91.9
190
87.8
8500
196.5
91.4
189
87.2
9000
195.5
90.8
188
86.7
9500
194.6
90.3
187
86.1
10000
193.7
89.8
186
85.6
9