-defined
range.
Here are the parameters that can be configured:
MONITORING MODE
Here can be modified the Load Monitoring mode. 3 modes are available.
- OFF: The Load Monitoring is turned off. The impedance is not measured, no alerts are raised.
- Internal Generator: The Load Monitoring uses an internal HF burst generator and this signal is used to
measure the impedance of the connected speakers.
- External generator: The Load Monitoring uses an external HF pilot tone (sent to the NXAMPmk2 with
the audio program) and this signal is used to measure the impedance of the connected speakers.