Note: An Alarm may sound at this time because the bat-
tery is not connected.
S
tep 6: CONNECT THE BATTERY:
Attach the battery cables to the battery, the BLACK wire to the
NEGATIVE(-) post, the RED wire to the POSITIVE (+) post and
tighten securely.
IMPORTANT: Check the ‘Battery Reverse’ LED on the
NexPump System Unit and if it is illuminated the connec-
tions are reversed.
S
tep
7: CHECK YOUR NEXPUMP:
All alarms should be off at this time. Check the mode setting
and set to your preferred setup (See Mode Selection -
NexPump Operation). The NexPump will schedule an auto-
matic self-test approximately two minutes after power up. If
there are any errors they will be displayed on the LCD display
and an alarm will sound.
S
tep 8: COVER AND SECURE BATTERY BOX:
If Battery Box was purchased, place Battery in Battery box,
secure Battery Box cover with the safety strap.
Step 9: PERFORM A
BATTERY RESET:
Check in Quick reference or Function Button section and per-
form a battery reset. This will enable the battery charge
process.
Note: Always perform a battery reset when replacing a
battery or installing a new system.
Your NexPump is ready for use!!