14 Setting pool heating
VWDUW JXLGH
DFWLYDWHG
VWDUW WHPS
VWRS WHPSHUDWXUH
r&
r&
SRRO
This part of the start guide is only displayed if the altern-
ative is selected in a previous menu and the accessory is
installed.
start temp
Setting range: 15.0 - 70.0 °C
Default value: 22.0 °C
stop temperature
Setting range: 15.0 - 70.0 °C
Default value: 24.0 °C
Select whether the pool control is to be activated and
within what temperatures (start and stop temperature)
pool heating must occur.
When the pool temperature drops below the set start
temperature and there is no hot water or heating require-
ment, F1145 starts pool heating.
Untick "activated" to switch off the pool heating.
Caution
The start temperature cannot be set to a value
that is higher than the stop temperature.
15 Setting cooling function
VWDUW JXLGH
FRROLQJ IORZ WHPS DW r&
FRRODQW IORZ OLQH DW r&
WLPH EHWZ VZLWFK KHDWFRRO
FORVH PL[ YDOYHV LQ FRRO PRGH
PLQ WHPS FRROLQJ IORZ
FRROLQJ
r&
KUV
r&
r&
This part of the start guide is only displayed if the altern-
ative is selected in a previous menu. In addition, it requires
either the accessory to be installed or that F1145 has an
integrated function for cooling.
min. temp. cooling flow
Setting range: 5 - 50 °C
Default value: 10
cooling flow temp. at +20 °C
Setting range: 5 - 50 °C
Default value: 20
coolant flow line at +40°C
Setting range: 5 - 50 °C
Default value: 15
time betw. switch heat/cool
Setting range: 0 - 48 h
Default value: 2
heat at room under temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
cool at room over temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
You can use F1145 to cool the house during hot periods
of the year.
min. temp. cooling flow
Set the minimum temperature on the supply temperature
to the climate system during cooling operation. This
means that F1145 never calculates a temperature lower
than that set here.
cooling flow temp. at +20 °C
Set the desired temperature on the flow temperature to
the climate system during cooling operation when the
outdoor temperature is +20 °C. F1145 then attempts to
get as close to the set temperature as possible.
coolant flow line at +40°C
Set the desired temperature on the flow temperature to
the climate system during cooling operation when the
outdoor temperature is +40 °C. F1145 then attempts to
get as close to the set temperature as possible.
time betw. switch heat/cool
Here you can set how long F1145 is to wait before it re-
turns to heating mode when the cooling demand has
ceased or vice versa.
NIBE™ F1145Chapter 6 | Commissioning and adjusting30