EasyManuals Logo

Nibe F1145 5 User Manual

Nibe F1145 5
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Set the minimum temperature on the supply temperature
to the climate system. This means that F1145 never cal-
culates a temperature lower than that set here.
If there is more than one climate system the setting can
be made separately for each system.
TIP
The value can be increased if you have, for ex-
ample, a cellar that you always want to heat,
even in summer.
You may also need to increase the value in "stop
heating" menu 4.9.2 "auto mode setting".
Menu 1.9.4 - room sensor settings
factor system
Setting range: 0.2 - 3.0
Default value: 2.0
Room sensors to control the room temperature can be
activated here.
Here you can set a factor that determines how much the
supply temperature is to be affected by the difference
between the desired room temperature and the actual
room temperature. A higher value gives a greater change
of the heating curve's set offset.
If several climate systems are installed the above settings
can be made for the relevant systems.
Menu 1.9.5 - cooling settings (accessory re-
quired)
min. temp. cooling flow
Setting range: 5 - 50 °C
Default value: 10
cooling flow temp. at +20 °C
Setting range: 5 - 50 °C
Default value: 20
coolant flow line at +40°C
Setting range: 5 - 50 °C
Default value: 15
time betw. switch heat/cool
Setting range: 0 - 48 h
Default value: 2
heat at room under temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
cool at room over temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
You can use F1145 to cool the house during hot periods
of the year.
min. temp. cooling flow
Set the minimum temperature on the supply temperature
to the climate system during cooling operation. This
means that F1145 never calculates a temperature lower
than that set here.
cooling flow temp. at +20 °C
Set the desired temperature on the flow temperature to
the climate system during cooling operation when the
outdoor temperature is +20 °C. F1145 then attempts to
get as close to the set temperature as possible.
coolant flow line at +40°C
Set the desired temperature on the flow temperature to
the climate system during cooling operation when the
outdoor temperature is +40 °C. F1145 then attempts to
get as close to the set temperature as possible.
time betw. switch heat/cool
Here you can set how long F1145 is to wait before it re-
turns to heating mode when the cooling demand has
ceased or vice versa.
NIBE™ F1145Chapter 8 | Control - Menus48