Safety valve
The function of the safety valve must be checked regularly. You can find
the safety valve on the incoming pipe (cold water) to the water heater.
Perform checks as follows:
1. Open the valve by turning the knob anti-clockwise carefully.
2. Check that water flows through the valve.
3. Close the valve by releasing it. If it does not close automatically when
released, turn it anti-clockwise slightly.
Saving tips
Your heat pump installation produces heat and hot water. This occurs via
the control settings you made.
Factors that affect the energy consumption are, for example, indoor tem-
perature, hot water consumption, the insulation level of the house and
whether the house has many large window surfaces. The position of the
house, e.g. wind exposure is also an affecting factor.
Also remember:
Open the thermostat valves completely (except in the rooms that are to
be kept cooler for various reasons, e.g. bedrooms). The thermostats slow
the flow in the heating system, which the heat pump wants to com-
pensate with increased temperatures. It then works harder and consumes
more electrical energy.
You can lower the temperature when away from the house by
scheduling "holiday setting" in menu 4.7. See page 65 for instructions.
If you activate "Hot water Economy", less energy is used.
Power consumption
Energiförbrukning fördelat över året
0%
5%
10%
15%
20%
jan
feb mars april maj juni juli aug sep okt nov dec
Månad
% av årsförbrukningen
The ground source heat pump's energy distribution is spread across
the year.
Month
Jan Feb Mar April May June July Aug Sep Oct Nov Dec
% of annual
consumption
Increasing the indoor temperature one degree increases the energy con-
sumption by approx. 5%.
23NIBE™ F1155Chapter 2 | The heat pump the heart of the house