temperature
temperature heating1.1.1
temperature cooling1.1.2
If the house has several climate sys-
tems, this is indicated on the display
by a thermometer for each system.
Choose between heating or cooling
and then set the desired temperature
in the next menu "temperature heat-
ing/cooling" in menu 1.1.
Set the temperature (with room
sensors installed and activated):
heating
Setting range: 5 30 °C
Default value: 20
cooling (accessory is required)
Setting range: 5 30 °C
Default value: 25
The value in the display appears as a
temperature in °C if the climate system is controlled by a room sensor.
Menu
1.1
Caution
A slow heat-releasing heating system, such as for example, underfloor
heating, may not be suitable for control using the heat pump's room
sensor.
To change the room temperature, use the control knob to set the desired
temperature in the display. Confirm the new setting by pressing the OK
button. The new temperature is shown on the right-hand side of the
symbol in the display.
Setting the temperature (without room sensors activated):
Setting range: -10 to +10
Default value: 0
The display shows the set values for heating (curve offset). To increase or
reduce the indoor temperature, increase or reduce the value on the display.
Use the control knob to set a new value. Confirm the new setting by
pressing the OK button.