heating curve
KHDWLQJ FXUYH
RXWGRRU WHPS r&
IORZ WHPSHUDWXUH r&
heating curve
Setting range: 0 - 15
Default value: 9
Menu
1.9.1
In the menu heating curve the so-called heating curve for your house can
be viewed. The task of the heating curve is to give an even indoor temperat-
ure, regardless of the outdoor temperature, and thereby energy efficient
operation. It is from this heating curve that the heat pump’s control computer
determines the temperature of the water to the heating system, flow line
temperature, and therefore the indoor temperature. You can select heating
curve and read off how the flow line temperature changes at different outdoor
temperatures here.
Curve coefficient
The slope of the heating curve indic-
ates how many degrees the supply
temperature is to be increased/re-
duced when the outdoor temperature
drops/increases. A steeper slope
means a higher supply temperature
at a certain outdoor temperature.
30
40
50
60
70
°C
- 40°C
UTETEMPERATUR
- 10
0
10
- 20 - 30
Brantare kurvlutning
6XSSO\ WHPSHUDWXUH
2XWGRRU WHPSHUDWXUH
6WHHSHU FXUYH VORSH
25NIBE™ F1226Chapter 3 | F1226 – at your service