INSTALLATION AREA
The distance between F2050 and the house wall must be at least 150 mm. The free space above F2050 must be at least
1,000 mm. The free space in front must be at least 1,000 mm for future servicing.
50
255
Ställbar 40-50 955
243
512
110
395
265
50
452
1075
1145
108
Ø40*
14
85
150 mm
Fritt utrymme bakom
Min. avstånd
vid användning
av flera F2040
600
mm
3000 mm
400 mm
600 mm
Minimalt
fritt utrymme
Minimalt
fritt utrymme
Fritt utrymme
framför
Free space behind
Min. distance when using
several F2050
Free space Free space
Free space in
front
1000 mm
Condensation
The condensate drain pan collects and leads away the con-
densation water.
NOTE
It is important to the heat pump function that
condensation water is led away and that the drain
for the condensation water run off is not posi-
tioned so that it can cause damage to the house.
Condensation run-off should be checked regularly,
especially during the autumn. Clean if necessary.
The condensation water (up to 50 litres / 24 hrs) must be
routed away by a pipe to an appropriate drain, it is recom-
mended that the shortest outdoor length possible is used.
The section of the pipe that can be affected by frost must
be heated by the heating cable to prevent freezing.
TIP
Pipe with heating cable for draining the condens-
ation water trough is not included.
Route the pipe downward from the heat pump.
The outlet of the condensation water pipe must be at frost
free depth.
Use a water trap for installations where air circulation may
occur in the condensation water pipe.
The insulation must seal against the bottom of the con-
densation water trough.
DRAIN PAN HEATER, CONTROL
The drain pan heater is supplied with power when one of
the following conditions is met:
1. The compressor has been in operation for at least 30
minutes after last start.
2. The ambient temperature is lower than 1 °C.
DRAINAGE OF CONDENSATION
Stone caisson
LEK
Frostfritt djup
Frost proof
depth
If the house has a cellar the stone caisson must be posi-
tioned so that condensation water does not affect the house.
Otherwise the stone caisson can be positioned directly under
the heat pump.
NIBE F2050Chapter 2 | Delivery and handling10