TECHNICAL DOCUMENTATION
F2050-6Model
Air-water
Exhaust-water
Brine-water
Water-water
Type of heat pump
Yes No
Low-temperature heat pump
Yes No
Integrated immersion heater for additional heat
Yes No
Heat pump combination heater
Average Cold Warm
Climate
Medium (55°C) Low (35°C)
Temperature application
EN14825 / EN14511 / EN12102Applied standards
%139ƞ
s
Seasonal space heating energy efficiencykW5.6PratedRated heat output
Declared coefficient of performance for space heating at part load and at
outdoor temperature Tj
Declared capacity for space heating at part load and at outdoor temperature
Tj
-1.95COPdTj = -7 °CkW5.0PdhTj = -7 °C
-3.51COPdTj = +2 °CkW2.9PdhTj = +2 °C
-4.99COPdTj = +7 °CkW1.9PdhTj = +7 °C
-6.33COPdTj = +12 °CkW1.7PdhTj = +12 °C
-1.95COPdTj = bivkW5.0PdhTj = biv
-1.75COPdTj = TOLkW4.6PdhTj = TOL
-COPdTj = -15 °C (if TOL < -20 °C)kWPdhTj = -15 °C (if TOL < -20 °C)
°C-10TOLMin. outdoor air temperature°C-7T
biv
Bivalent temperature
-COPcycCycling interval efficiencykWPcychCycling interval capacity
°C58WTOLMax supply temperature-0.96CdhDegradation coefficient
Additional heatPower consumption in modes other than active mode
kW1.0PsupRated heat outputkW0.007P
OFF
Off mode
kW0.011P
TO
Thermostat-off mode
ElectricType of energy inputkW0.011P
SB
Standby mode
kW0.000P
CK
Crankcase heater mode
Other items
m
3
/h2,340Rated airflow (air-water)VariableCapacity control
m
3
/hNominal heating medium flowdB- / 53L
WA
Sound power level, indoors/outdoors
m
3
/hBrine flow brine-water or water-water heat
pumps
kWh3,250Q
HE
Annual energy consumption
NIBE Energy Systems Box 14 Hannabadsvägen 5 285 21 Markaryd SwedenContact information