EasyManua.ls Logo

Nibe F730 - Page 42

Nibe F730
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TIP
Wait 24 hours before making a new setting, so that the room temper-
ature has time to stabilise.
If it is cold outdoors and the room temperature is too low, increase
the curve slope by one increment.
If it is cold outdoors and the room temperature is too high, lower the
curve slope by one increment.
If it is warm outdoors and the room temperature is too low, increase
the curve offset by one increment.
If it is warm outdoors and the room temperature is too high, lower the
curve offset by one increment.
EXTERNAL ADJUSTMENT
external adjustment1.9.2
climate system 1
climate system 2
climate system 3
climate system 4
°C
°C
climate system
Setting range: -10 to +10.
Or desired room temperature if the
room sensor is installed. See illustra-
tion.
Default value: 0
Menu
1.9.2
Connecting an external contact, for example, a room thermostat or a timer allows
you to temporarily or periodically raise or lower the room temperature while
heating. When the contact is on, the heating curve offset is changed by the
number of steps selected in the menu. If a room sensor is installed and activated
the desired room temperature (°C) is set.
If there is more than one climate system the setting can be made separately for
each system.