EasyManua.ls Logo

Nibe MODBUS 40 - Troubleshooting; MODBUS 40 no contact issues; Technical data

Nibe MODBUS 40
44 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
MODBUS 40 has no contact with the heat
pump/indoor module (does not respond)
MODBUS 40 is not activated in heat pump/indoor
module menu 5.2 (menu 5.2.4 for NIBE F1345,
VVM 310, VVM 320, VVM 325 and VVM 500).
Incorrectly connected cables between MODBUS 40
and heat pump/indoor module. Gives a communica-
tion alarm in the heat pump's/indoor module's dis-
play.
Incorrect software in the heat pump. The software
version in the heat pump must be higher than 3000.
NOTE
Find more information about MODBUS 40 at
www.nibe.se/kommunikation.
Technical data
Technical specifications
12 VDC 45-80 mARated voltage
067 144Part No.
154 x 108 x 40 mmDimensions
20
GB

Table of Contents

Related product manuals