In multi-installations with several heat pumps, some menus are also visible in the display on the heat pumps that
are not the main unit.
Menu 1 Indoor climate
OVERVIEW
1.1.1 - Heating1.1 - Temperature
1.1.2 - Cooling
1
1.1.3 - Humidity
1
1.2.1 - Fan speed
1
1.2 - Ventilation
1
1.2.2 - Night cooling
1
1.2.3 - FLM cooling
1
1.2.4 - Demand-controlled ventilation
1
1.2.5 - Fan return time
1
1.2.6 - Filter cleaning interval
1
1.3 - Room sensor settings
1.4 - External impact
1.5 - Climate system name
1.30.1 - Curve, heating1.30 - Advanced
1.30.2 - Curve, cooling
1
1.30.3 - External adjustment
1.30.4 - Lowest supply heating
1.30.5 - Lowest supply cooling
1
1.30.6 - Highest supply heating
1.30.7 - Own curve
1.30.8 - Point offset
1
Consult the accessory’s Installer Manual.
MENU 1.1 TEMPERATURE
You make temperature settings for S1155 here.
In installations with several climate systems, temperat-
ure settings can be made for each system.
MENU 1.1.1 - HEATING
Heating
Set the temperature (with room sensor installed
and activated):
Setting range: 5 30 °C
The value in the display appears as a temperature in °C,
if the zone is controlled by a room sensor.
Caution
A slow heating system such as underfloor
heating may be inappropriate for controlling
with room sensors.
Setting the temperature (without room sensors
activated):
Setting range: -10 10
NIBE S1155Chapter 9 | Control - Menus40