ACCESSIBILITY, ELECTRICAL CONNECTION
Removing the cover
The cover is opened using a screwdriver.
Removing the covers
The cover is opened using a screwdriver.
CABLE LOCK
Use a suitable tool to release/lock cables in the heat pump
terminal blocks.
Terminal block
TEMPERATURE LIMITER
-X29
-X28
1 0-5V
2 +5V
3 AUX1
4 AUX2
5 AUX3
6 AUX4
7 AUX5
8 AUX6
9 AUX7
10 AUX8
11 AUX9
12 BT25
1
1
2
3
2
3
4
5
6
7
8
9
10
11
12
GND
+12V
B
A
OT+
OT−
0-5V
PWM0
PWM1
CPU
EXT COM
INT COM
ERROR
POWER
+5V
GND
BE1
BE2
BE3
K10
-X27
NO
O
NC
AUX
-RELAY
13 BT50
14 BT1
-X30
FQ10-S2
The temperature limiter (FQ10) cuts the power supply to the
electric additional heat if the temperature rises above 89 °C
and it is reset manually.
Resetting
The temperature limiter (FQ10) is accessed behind the front
cover. Reset the temperature limiter by pressing its button
(FQ10-S2).
19Chapter 5 | Electrical connectionsNIBE S1255