TARIFF CONTROL
If the control is to be supplied separately from other
components in the heat pump (e.g. for tariff connection),
a separate operating cable must be connected to termin-
al block (X5).
If external control voltage is used during tariff control,
connect a closing contact to connection X21:1 and X21:2
(compressor blocking) to prevent an alarm. Compressor
blocking must be performed either on the indoor mod-
ule/control module or on the air/water heat pump, not
on both simultaneously.
S2125
2
1
AA2:X21
CONNECTING EXTERNAL CONTROL
VOLTAGE
NOTE
Mark up any junction boxes with warnings for
external voltage.
When connecting external control voltage, remove the
bridges from terminal block X5 (see image).
L
EK
L
0
4.
2.
3.
1.
Connect external control voltage (230V~ 50Hz) to termin-
al block X5:L, X5:N and X5:PE (as illustrated).
F2120 Externt
AA2:X5
N
L
N
L