General pipe connections
Pipe installation must be carried out in accordance with
current norms and directives.
Symbol key
MeaningSymbol
Control valve
Shunt / shuttle valve
Temperature sensor
Expansion vessel
Circulation pump
Fan
Compressor
Heat exchanger
Outline diagram
-EB100
-AZ2
-CP1
Caution
If the total circulating volume in the climate
system (excluding the heat pump volume) falls
below 40 litres, extra system volume is connec-
ted, for example volume vessel UKV (CP1) ac-
cording to the outline diagram above.
NOTE
If several climate systems (ECS 40/ECS 41) are
present, SAM 40 must be connected in parallel
with climate system 1. A circulation pump must
be used to ensure the flow over SAM 40.
SAM 40Chapter 4 | Pipe and ventilation connections10
4 Pipe and ventilation connections