Energy labelling
NIBESupplier
SAM 40Model
Average: -11.0
Cold: -28.9
Warm: 0.7
kWh/(m
2
year)
Specific energy consumption (SEC)
E
Energy efficiency class
RVU, UnidirectionalDeclared typology
Variable speed driveType of drive
NoneType of heat recovery system
0Thermal efficiency of heat recovery
290m
3
/hMaximum air flow rate
108WElectric power input of the fan drive at maximum flow
rate
50dBSound power level (LWA)
0.0583 (210)m
3
/s (m
3
/h)Reference flow rate
78PaReference pressure difference
0.262W/m
3
/hSpecific power input (SPI)
Clock control (0.95)Control factor and control typology
< 3%External leakage rates
See user manual.Information about filter warning
See section General ventilation connection on page 16.Information about supply/exhaust grilles in the facade
See section Recovery on page 4.
This installer manual can also be accessed at www.nibe.eu.
Information about pre-/disassembly
312kWh/yearThe annual electricity consumption
Average: 1,874
Cold: 3,667
Warm: 848
kWh
prim/year
Annual heating saved, kWh primary energy per year
SAM 40Chapter 9 | Technical data26