Transport
The supply air module must be transported and stored
dry.
Assembly
SAM 40 is mounted free standing on brackets, altern-
atively above a VPB 200 (For VPB 300/VPBS 300 install-
ation is with the help of brackets). Noise from the fan
can be transferred to the brackets.
Install the brackets to an outside wall, ideally in a
room where noise does not matter, in order to elim-
inate noise problems. If this is not possible, avoid
placing it against a wall behind a bedroom or other
room where noise may be a problem.
Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
Route pipes so they are not fixed to an internal wall
that backs on to a bedroom or living room.
Installation area
Leave a free space of 500 mm in front of the supply air
module. All service on SAM 40 can be carried out from
the front.
800
NOTE
Ensure that there is sufficient space (300 mm)
above the supply air module for installing
ventilation hoses.
Removing the covers
Front cover
1.
Remove the service cover by pulling it straight out.
7Chapter 2 | Delivery and handlingSAM 40