Menu system
If you do not make all settings via the start guide or
need to change any of the settings, this can be done
in the menu system.
Menu 5.2 -system settings
Activating/deactivating of accessories.
Select: "ext sup air md"
Caution
This accessory may require a program software
update in your F750.
The heat pump software must be version
3585R2 or later.
Setting the ventilation
Ventilation must be set according to applicable stand-
ards. The supply air flow is adjusted so that it is 80%
of the exhaust air flow. The setting is made in menu
5.1.6.
Even if ventilation is roughly set at installation it is im-
portant that a ventilation adjustment is ordered and
permitted.
NOTE
Order a ventilation adjustment to complete
the setting.
Tillgängligt
tryck
(Pa)
Luftflöde
(m3/h)
(l/s)
0
50
100
150
200
250
300
350
400
0 50 100 150 200 250 300
40%
50%
80%
90/100%
60%
70%
20 40 60 80
Airflow
Available
pressure
(Pa)
Fan capacity pressure
Effekt
(W)
Luftflöde
(m3/h)
(l/s)
20
40
60
80
100
120
0 50 100 150 200 250 300
0
20 40 60 80
40%
50%
80%
90/100%
60%
70%
Fan capacity output
Power
output
(W)
Airflow
19Chapter 6 | Commissioning and adjustingSAM 40