op. mode
Setting range: auto, manual, add.
heat only
Default value: auto
functions
Setting range: compressor, addi-
tion, heating, cooling
Menu
4.2
The control module operating mode is usually set to "auto". It is also pos-
sible to set the control module to "add. heat only", when only additional
heat is used, or "manual" and then select what functions are to be permit-
ted.
Change the operating mode by marking the desired mode and pressing
the OK button. When an operating mode is selected it shows what in the
control module is permitted (crossed out = not permitted) and selectable
alternatives to the right. To select selectable functions that are permitted
or not, mark the function using the control knob and press the OK button.
Operating mode auto
In this operating mode the control module automatically selects what
functions are permitted.
Operating mode manual
In this operating mode you can select what functions are permitted. You
cannot deselect "compressor" in manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active, only additional heat
is used.
Caution
If you choose mode "add. heat only" the compressor is deselected and
there is a higher operating cost.
NIBE™ SMO 20Chapter 3 | SMO 20 – at your service54