start cooling (accessory
required)
Setting range: 15 – 40 °C
Factory setting: 25
stop heating
Setting range: -20 – 40 °C
Default values: 17
stop additional heat
Setting range: -25 – 40 °C
Factory setting: 5
filtering time
Setting range: 0 – 48 h
Default value: 24 h
Menu
4.9.2
When the operating mode is set to "auto", the control module selects
when start and stop of additional heat and heat production is permitted,
depending on the average outdoor temperature. If the heat pump has
the integrated cooling function and it is activated in the menu you can
also select the start temperature for cooling.
Select the average outdoor temperatures in this menu.
You can also set the time over which (filtering time) the average temper-
ature is calculated. If you select 0, the present outdoor temperature is
used.
Caution
It cannot be set "stop additional heat" higher than "stop heating".
Caution
In systems where heating and cooling share the same pipes "stop heat-
ing" cannot be set higher than "start cooling" if there is not a cool-
ing/heating sensor.
NIBE™ SMO 20Chapter 3 | SMO 20 – at your service58