degree minute setting
current value
start compressor
start diff additional heat
diff. between additional steps
DM
DM
DM
DM
degree minute setting4.9.3
current value
Setting range: -3000 3000
start compressor
Setting range: -1000 -30
Default value: -60
step difference compressors
Setting range: 10 2000
Default value: 60
start diff additional heat
Setting range: 100 2000
Factory setting: 400
diff. between additional steps
Setting range: 10 1000
Factory setting: 30
Menu
4.9.3
Degree minutes are a measurement of the current heating requirement
in the house and determine when the compressor respectively additional
heat will start/stop.
Caution
Higher value on "start compressor" gives more compressor starts, which
increase wear on the compressor. Too low value can give uneven indoor
temperatures.
factory setting user
Do you want to reset all user settings to
factory settings?
factory setting user 4.9.4
yes
no
All settings that are available to the
user (including advanced menus) can
be reset to default values here.
Menu
4.9.4
Caution
After factory setting, personal set-
tings such as heating curves must
be reset.