EasyManua.ls Logo

Nibe SMO 20 - Schedule Blocking; Blocking Features by Schedule

Nibe SMO 20
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
schedule blocking
activated
schedule 2schedule 1
all
mon
tues
wed
thur
fri
sat
sun
schedule blocking 4.9.5
Activated
Schedule
Time period BlockingDay Conflict
The additional heat can be scheduled
to be blocked for up to two different
time periods here.
When scheduling is active the relevant
blocking symbol is shown in the main
menu on the symbol for the control
module.
Schedule: The period to be changed
is selected here.
Activated: Scheduling for the selected
period is activated here. Set times are
not affected at deactivation.
Day: Select which day or days of the
week the schedule is to apply to here. To remove the scheduling for a
particular day, the time for that day must be reset by setting the start time
to the same as the stop time. If the line "all" is used, all days in the period
are set for these times.
Menu
4.9.5
Time period: The start and stop time for the selected day for scheduling
are selected here.
Blocking: The desired blocking is selected here.
Conflict: If two settings conflict with each other a red exclamation mark
is displayed.
Blocking the compressor in the outdoor unit.
Blocking additional heat.
TIP
If you wish to set similar scheduling for every day of the week start by
filling in all” and then changing the desired days.
TIP
Set the stop time earlier than the start time so that the period extends
beyond midnight. Scheduling then stops at the set stop time the day
after.
Scheduling always starts on the date that the start time is set for.
NIBE™ SMO 20Chapter 3 | SMO 20 at your service60