TEMPERATURE SENSOR, HOT WATER
CHARGING
The temperature sensor, hot water charging (BT6) is
placed in the submerged tube on the water heater.
Connect the sensor to terminal block X6:7 and X6:8 on
the input board (AA3). Use a twin core cable with a cable
area of at least 0.5 mm².
Hot water charging is activated in menu 5.2 or in the
start guide.
SMO Externt
6
7
8
9
10
11
12
1
3
AA3-X6
ExternalSMO40
BT6
L N 1 1 0 2 3 4PE
1 2 3 4
LEK
AA3-X6
TEMPERATURE SENSOR, HOT WATER TOP
A temperature sensor for hot water top (BT7) can be
connected to SMO 40 to show the water temperature
at the top of the tank (if it is possible to install a sensor
at the top of the tank).
Connect the sensor to terminal block X6:15 and X6:16
on the input board (AA3). Use a twin core cable with a
cable area of at least 0.5 mm².
SMO Externt
11
12
13
14
15
16
17
1
8
AA3-X6
ExternalSMO40
BT7
L N 1 1 0 2 3 4PE
1 2 3 4
LEK
AA3-X6
TEMPERATURE SENSOR, EXTERNAL FLOW
LINE
Connect temperature sensor, external supply line (BT25)
(required for additional heat after reversing valve
(QN10)), to terminal block X6:5 and X6:6 on the input
board (AA3). Use a twin core cable with a cable area of
at least 0.5 mm².
SMO Externt
4
5
6
7
8
9
10
1
1
AA3-X6
ExternalSMO40
BT25
L N 1 1 0 2 3 4PE
1 2 3 4
LEK
AA3-X6
TEMPERATURE SENSOR, EXTERNAL
RETURN LINE
Connect temperature sensor, external return line (BT71)
to terminal block X6:17 and X6:18 on the input board
(AA3). Use a twin core cable with a cable area of at least
0.5 mm².
SMO Externt
11
12
13
14
15
16
17
1
8
AA3-X6
ExternalSMO40
BT71
L N 1 1 0 2 3 4PE
1 2 3 4
LEK
AA3-X6
Caution
For docking that requires connection of other
sensors, see "Possible selection for AUX in-
puts" on page 30.
NIBE SMO 40Chapter 5 | Electrical connections26