Miscellaneous
Indoor module
17litreVolume loop
270litreVolume, total indoor module
50litreVolume buffer vessel
1.0 (10 bar)MPa (bar)Cut-off pressure, loop
0.3 (3 bar)MPa (bar)Max permitted pressure in indoor module
Capacity hot water heating
According to EN 255-3
See diagram, page 49litreTap volume 40 °C at Eco- comfort
See diagram, page 49litreTap volume 40 °C at Normal comfort
See diagram, page 49litreTap volume 40 °C at Lux comfort
Dimensions and weight
600mmWidth
615mmDepth
1800mmHeight (without base)
1830 – 1850mmHeight (with base)
1910mmRequired ceiling height
140kgWeight (excl. packaging and without water)
069 430Part no.
622 40 85RSK No.
Hot water capacity
0
2
4
6
8
10
12
14
16
18
20
0
50 100 150 200 250 300 350 400 450 500
Tappflöde (l/m)
Volym varmvatten (liter)
Varmvattenkapacitet VVM310
Ekonomi
Ekonomi
Normal
Normal
Lyx
Lyx
Volume hot water (litres)
Tap flow
(litres/minute)
Economy
Normal
Lux
Economy Normal Lux
49Chapter 8 | Technical dataNIBE™ VVM 310