EasyManuals Logo

Nibe VVM 310 Service Manual

Nibe VVM 310
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
Miscellaneous
Indoor module
17litreVolume loop
270litreVolume, total indoor module
50litreVolume buffer vessel
1.0 (10 bar)MPa (bar)Cut-off pressure, loop
0.3 (3 bar)MPa (bar)Max permitted pressure in indoor module
Capacity hot water heating
According to EN 255-3
See diagram, page 49litreTap volume 40 °C at Eco- comfort
See diagram, page 49litreTap volume 40 °C at Normal comfort
See diagram, page 49litreTap volume 40 °C at Lux comfort
Dimensions and weight
600mmWidth
615mmDepth
1800mmHeight (without base)
1830 1850mmHeight (with base)
1910mmRequired ceiling height
140kgWeight (excl. packaging and without water)
069 430Part no.
622 40 85RSK No.
Hot water capacity
0
2
4
6
8
10
12
14
16
18
20
0
50 100 150 200 250 300 350 400 450 500
Tappflöde (l/m)
Volym varmvatten (liter)
Varmvattenkapacitet VVM310
Ekonomi
Ekonomi
Normal
Normal
Lyx
Lyx
Volume hot water (litres)
Tap flow
(litres/minute)
Economy
Normal
Lux
Economy Normal Lux
49Chapter 8 | Technical dataNIBE™ VVM 310

Other manuals for Nibe VVM 310

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe VVM 310 and is the answer not in the manual?

Nibe VVM 310 Specifications

General IconGeneral
BrandNibe
ModelVVM 310
CategoryHeat Pump
LanguageEnglish

Related product manuals