Miscellaneous
Indoor module
17litreVolume loop
270litreVolume, total indoor module
50litreVolume buffer vessel
1.0 (10 bar)MPa (bar)Cut-off pressure, loop
0.3 (3 bar)MPa (bar)Max permitted pressure in indoor module
Capacity hot water heating
According to EN 255-3
See diagram, page 49litreTap volume 40 °C at Eco- comfort
See diagram, page 49litreTap volume 40 °C at Normal comfort
See diagram, page 49litreTap volume 40 °C at Lux comfort
Dimensions and weight
600mmWidth
615mmDepth
1800mmHeight (without base)
1830 1850mmHeight (with base)
1910mmRequired ceiling height
140kgWeight (excl. packaging and without water)
069 430Part no.
622 40 85RSK No.
Hot water capacity
0
2
4
6
8
10
12
14
16
18
20
0
50 100 150 200 250 300 350 400 450 500
Tappflöde (l/m)
Volym varmvatten (liter)
Varmvattenkapacitet VVM310
Ekonomi
Ekonomi
Normal
Normal
Lyx
Lyx
Volume hot water (litres)
Tap flow
(litres/minute)
Economy
Normal
Lux
Economy Normal Lux
49Chapter 8 | Technical dataNIBE™ VVM 310